400LP INSTALLATION MANUAL © 2013 Aqua-Hot Heating Systems Inc. AVERTISSEMENT. Assurez-vous de bien suivre les instructions données dans cette notice
© 2013 Aqua-Hot® 400-LP Installation Manual 4. Insert a #10 machine screw into each of the embossed holes in the mounting tray (total of si
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 2: AQUA-HOT INSTALLATION — Page 11 — Figure 7 15.27”
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 2: AQUA-HOT INSTALLATION Figure 8 — Page 12 —
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 2: AQUA-HOT INSTALLATION Figure 9 — Page 13 — 1/2 in. 1/2 in. Aqua Hot 400-LP
© 2013 Aqua-Hot® 400-LP Installation Manual NOTE: Avoid any dips and bends in the overflow tubing from the Aqua-Hot to the expansion tank as air ca
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Heat Exchanger Locations and Clearances: • Place the heat excha
© 2013 Aqua-Hot® 400-LP Installation Manual Figure 13 Figure 14 Indicates sample mounting locations for the Cozy heat exchangers. Actual placement
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Mounting the Heat Exchangers: 1. Cut out a 2.5 inch H x 10 inch W op
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Figure 19 — Page 18 — Figure 18
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Figure 20 — Page 19 — Wiring the Heat Exchangers: 1. Run two 18-g
CAUTION: The Aqua-Hot tank and heating loop operate at 0.0 psi (zero pressure system). Air pressure applied to the tank MUST NOT exceed 20 psi. Exces
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM When wiring the heat exchangers in-parallel, the main 18-gau
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Plumbing Requirements: Once all heat exchangers have been moun
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Plumbing the Hydronic Heating System: 1. Lay out the plumbing lines
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 3: HYDRONIC HEATING SYSTEM Figure 25 Figure 26 — Page 23 — Barbed Fittings Components Compre
© 2013 Aqua-Hot® 400-LP Installation Manual Figure 27 — Page 24 — Outlet Heating Loop Connection Examples SECTION 3: HYDRONIC HEATING SYSTEM Str
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 4: THERMOSTATS Fresh Water Tank Thermostat Locations: Select a location that will ensure
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 4: THERMOSTATS Room Thermostat Locations: Select a location that will ensure even-heat through
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 5: DOMESTIC WATER SYSTEM Domestic Water System Requirements: NOTE: Please note that it may be n
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 5: DOMESTIC WATER SYSTEM Figure 30 Figure 31 — Page 28 — Domestic Hot Water Outlet Domestic
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 6: SWITCH PANEL Switch Panel Location: 1. Select a location in the interior of the coach that
© 2013 Aqua-Hot® 400-LP Installation Manual TABLE OF CONTENTS Aqua-Hot 400-LP Installation Manual Introduction ...
© 2013 Aqua-Hot® 400-LP Installation Manual NOTE: The electric element switch possess a jumper wire, which advance from terminal 3 to terminal 4. S
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 7: PROPANE CONNECTION Ensure that all tubing and fittings obey all local, state, and nat
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 7: PROPANE CONNECTION Figure 35 — Page 32 — NOTE: The 400 LP and Manual Shut-off Valve mus
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 8: EXHAUST SYSTEM — Page 33 — NOTE: Should the particular application require more than
© 2013 Aqua-Hot® 400-LP Installation Manual — Page 34 — NOTE: A maximum of one 90° and one 45° Bend is allowed for the exhaust pipe. Also, th
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 8: EXHAUST SYSTEM Figure 38 — Page 35 — 400LP 400LP Exhaust Tip Exhaust Tip Figure 39
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 8: EXHAUST SYSTEM 3” Black Pipe Nipple Installed Black Pipe Elbow 4” Black Pipe Nippl
© 2013 Aqua-Hot® 400-LP Installation Manual — Page 37 —
© 2013 Aqua-Hot® 400-LP Installation Manual — Page 38 —
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 9: ELECTRONIC CONTROLLER WIRING Electronic Controller Wiring: NOTE: Please reference Appendix A
Section 8: Exhaust System Exhaust System Requirements ...
© 2013 Aqua-Hot® 400-LP Installation Manual DO NOT activate the burner until the antifreeze and water heating solution has been added to the boiler
© 2013 Aqua-Hot® 400-LP Installation Manual Main Battery Disconnect SECTION 9: ELECTRONIC CONTROLLER WIRING — Page 41 — Connecting the 12 Volt-DC
© 2013 Aqua-Hot® 400-LP Installation Manual Air Release Valve Expansion Tank Connection SECTION 10: PURGING THE SYSTEMS Only propylene glycol b
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 10: PURGING THE SYSTEMS 3. Fill the Aqua-Hot completely with the 50/50 mixture of antifreeze a
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 10: PURGING THE SYSTEMS — Page 44 — Zone 1 Circulation Pump Zone 2 Circulation Pump Figure
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 10: PURGING THE SYSTEMS — Page 45 — NOTE: The propane burner may not light on the fi
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 11: INITIAL START-UP — Page 46 —
— Page 47 — SECTION 11: INITIAL START-UP Activating the Aqua-Hot: 1. Reinstall the Aqua-Hot’s main access cover and the fastener, which secures t
APPENDIX A: WIRING DIAGRAM — Page 48 — Burner 0 Burner I
APPENDIX B: WIRE GAUGE INFORMATION — Page 49 —
© 2013 Aqua-Hot® 400-LP Installation Manual INTRODUCTION Danger, Warning, Caution, and Note Boxes: Danger, Warning, Caution, and Note boxes appear t
© 2013 Aqua-Hot® 400-LP Installation Manual APPENDIX C: ELECTRONIC CONTROLLER FEATURES Terminals Strips with Screw-Type Fasteners: The electronic
© 2013 Aqua-Hot® 400-LP Installation Manual APPENDIX C: ELECTRONIC CONTROLLER FEATURES “Low Voltage Reset” Feature: Whenever the Aqua-Hot’s DC powe
© 2013 Aqua-Hot® 400-LP Installation Manual — Page 52 — APPENDIX D: ANTIFREEZE TYPES The following information addresses the necessary usage of
APPENDIX F: ANTIFREEZE TERMS AND MIXTURE RATIO — Page 53 — Propylene Glycol Based Antifreeze Solution: The following information addresses the pr
APPENDIX F: ANTIFREEZE TERMS AND MIXTURE RATIO — Page 54 —
© 2013 Aqua-Hot® 400-LP Installation Manual Figure 1 Eyepiece Calibration Screw Daylight Plate Assembly Main Prism Assembly CALIBRATE THE REFRACTOM
© 2013 Aqua-Hot® 400-LP Installation Manual Warning 1. Use extreme caution in gathering your antifreeze sample. When draining the Aqua-Hot heating
© 2013 Aqua-Hot® 400-LP Installation Manual
LTE-400-010 15549 East Highway 52 | Fort Lupton, CO 80621 Toll free: 800.685.4298 | phone: 303.659.8221 | fax:303.857.9000 www.aquahot.com
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 1: AQUA-HOT HYDRONIC HEATING SYSTEM Propane Burner, Heat Input (Firing Rate) ...
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 1: AQUA-HOT HYDRONIC HEATING SYSTEM Each Aqua-Hot heating system possesses an I.D. label on the
© 2013 Aqua-Hot® 400-LP Installation Manual Figure 3 Propane Inlet Ball Valve Drain Valve VAC Access Panel AC Terminal Port Propane Burner Heating Z
© 2013 Aqua-Hot® 400-LP Installation Manual SECTION 1: AQUA-HOT HYDRONIC HEATING SYSTEM — Page 9 — Figure 5 AC Wiring Port Zone 1 and 2 Outlet Po
Comentários a estes Manuais